2.5 Function Description
The function of the amplifier is described by means of the block diagram shown in Figure
2.
2.5.1 Power Supply
Power amplifier:
Rectification and filtering form the direct voltage (intermediate circuit voltage UB),
necessary to operate the power amplifier, from the AC power supply. This
intermediate circuit voltage can also be fed directly as d.c. voltage.
Electronic supply
The electronic supply takes place internally through a switched-mode power supply
from the intermediate circuit voltage.
2.5.2 Control System
Speed controller and current limiting
The nominal speed value can be fed through the input differential amplifier. In the
stage connected on load side the positive and negative set values are suppressed
separately (limit switch logic). The speed set value, conditioned by this way, is then
injected to the speed controller. The inverted tachometer voltage, injected to the speed
controller, in this device, is gained from the resolver signals, by means of a
corresponding procedure. The current set value is then available at the output of the
speed controller.
There are different possibilities to limit the nominal current:
The I
2
t current limiting reduces the current set value, using the following procedure:
The actual current values are rectified, quadrated and run to a low pass. The circuit
limits the current to the continuous current value, which corresponds to the position of
the potentiometer P5, when the output voltage of the low pass reaches the voltage,
adjusted at this potentiometer. Furthermore, the maximum possible nominal current
can be adjusted to 0...15A, 0...25A or 0...18A with an externally fed voltage of 0...10V
at the input Iext.
The maximum pulse current, deliverable by the device can be adjusted with the
potentiometer P2 of the internal current limiting. This current limiting is connected on
load side of the previously mentioned current limitations - this guarantees that the
current adjusted here, can never by exceeded.