MTS Systems Series TBF-R User Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 51
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
20
3.2.2 Connector 2 (D-SUB/9-pins/socket)
Connector 2 is intended for connecting a resolver. A two-pole transmitter with a
transformation ratio of 0.5 is required as resolver. The input voltage of the rotor should be
suitable for 7Vrms
with 10kHz.
1 S4-Resolver Input for the stator signal S4 of a two-pole resolver.
2 S2-Resolver Input for the stator signal S2 of a two-pole resolver.
3 S3-Resolver Input for the stator signal S3 of a two-pole resolver.
4 S1-Resolver Input for the stator signal S1 of a two-pole resolver.
5 R1-Resolver Output of the 7Vrms /10kHz reference signal for the rotor
connection R1 of the resolver.
6 Shield Contact to connect the shielding of the resolver line, e.g.
common shield S4/S2 and common shield S1/S3.
7 Shield Contact to connect the shielding of the resolver line, e.g.
common shield R1/R2.
8 Shield Contact to connect the shielding of the resolver line, e.g. total
shielding.
9 R2-Resolver Connection for the resolver R2. This connection is internally
connected to GND.